10/6/2019 Edi 1300 Keygen
PERKINS WK 1300 SERIES EDI USER HANDBOOK MANUAL Pdf Download. View and Download Perkins WK 1300 Series EDi user handbook manual online. WK 1300 Series EDi Engine pdf manual download. Also for: Wl 1300 series edi, Wn 1300 series edi, Wp 1300. 'Perkins Diesel Engine Identification & Serial Number Guide'. Perkins SPI2 v2012A Heavy. Perkins keygen est perkins keygen perkins est 2015a keygen perkins spi2 2015a keygen perkins edi 1300 keygen perkins est 2011b keygen perkins est 2010b keygen.
Perkins EDi is a diagnostic software for electronic engines. The Perkins Peregrine EDi/1300 Series EDi is a family of turbocharged engines that have an electronic management system. The Peregrine EDi engines are designed for automotive applications and the 1300 Series EDi engines are designed for industrial and agricultural applications. The Peregrine EDi and the 1300 Series EDi engines are from Perkins Engines Company Limited, a world leader in the design and manufacture of high-performance diesel engines.
The Perkins Diagnostic Tool for the Peregrine EDi and 1300 Series EDi offers the following functionality:. View Data Lists. Create Custom Data Lists. View and Clear Diagnostic Codes.
View Programmable Parameters. Reset Customer Programmable Parameters.
Perform Diagnostic Tests. Record Engine Data Over a Specific Time.
. TPD1352E, Issue 4 November 2011 User’s Handbook 1300 Series EDi.
T his publication is written in P erkins Approved Clear E nglish This publication is divided into six chapters: 1 General information 2 Engine views 3 Operation instructions 4 Preventive maintenance 5 Engine fluids 6 Fault diagnosis The following pages contain a detailed table of contents. 1300 Series EDi Models WK to WS Contents 1 General information Introduction.1 Safety precautions. 1300 Series EDi Models WK to WS 4 Preventive maintenance Preventive maintenance periods.17 Schedules.18 How to drain the cooling system. The 1300 Series EDi is a family of engines which have an electronic management system. The engines are designed for industrial and agricultural applications from Perkins Engines Limited, a world leader in the design and manufacture of high-performance diesel engines. 1300 Series EDi Models WK to WS Safety precautions These safety precautions are important. You must refer also to the local regulations in the country of use.
Some items only apply to specific applications. Only use these engines in the type of application for which they have been designed. Do not change the specification of the engine. Renew the filter canisters and lubricating oil regularly in order to ensure that the inside of your engine remains clean. Ensure that all adjustments and repairs are done by personnel who have had the correct training.
Perkins distributors have this type of personnel available. You can also obtain parts and service from your Perkins distributor.
Use these procedures after the engine is withdrawn from service. Procedure Caution: The procedure for this engine is different to the procedure for other Perkins engines, because of the design of the fuel injection units. 180 degrees. Visibly check for damage or corrosion to the engine. If the engine protection is done correctly according to the above recommendations, no corrosion damage will normally occur. Perkins are not responsible for damage which may occur when an engine is in storage after a period in service. 1296 = Build list number N = Built in the USA 123456U = Engine serial number If you need parts, service or information for your engine, you must give the complete engine number to your Perkins distributor.
User’s Handbook, TPD 1352E, issue 4. 1300 Series EDi Models WK to WS W002 PW250/1 User’s Handbook, TPD 1352E, issue 4.
1300 Series EDi Models WK to WS Engine data Number of cylinders.6 Cylinder arrangement. 1300 Series EDi Models WK to WS User’s Handbook, TPD 1352E, issue 4. This page is intentionally blank. 1300 Series EDi Models WK to WS Engine views Introduction Perkins engines are built for specific applications and the views which follow do not necessarily match your engine specification. Location of engine parts Front and left side view 1 Fan. 1300 Series EDi Models WK to WS Rear and right side view 16 Rear lift bracket 24 Front lift bracket 17 Engine breather pipe 25 Coolant temperature sensor 18 Turbocharger 26 Alternator 19 Wastegate 27 Tensioner for the drive belt 20 Flywheel 28 Canister for the coolant filter / inhibitor 21 Flywheel housing. 1300 Series EDi Models WK to WS Operation instructions How to start the engine Temperature of 15°C (60°F) to -10°C (14°F) Several factors affect engine start, for example: The power of the batteries The performance of the starter motor The viscosity of the lubricating oil The installation of a cold start system.
1300 Series EDi Models WK to WS 5 Locate and correct the problem. Always ensure that the engine and starter motor are stationary before the starter motor is engaged again. When the engine starts, check that the lubricating oil pressure exceeds 138 kPa (20 lbs/in ) 1,4 kgf/cm within the first 10 seconds, see 'Engine data'. 1300 Series EDi Models WK to WS How to start an engine with an ether start system Ambient temperature below -20°C (-4°F) Caution: Ether is very flammable and is toxic. Apply the safety precautions on the container for the use and storage of ether and for the disposal of empty containers.
1300 Series EDi Models WK to WS How to stop the engine Turn the engine start key to the 'OFF' position. It is recommended that the engine is operated at idle speed for three to five minutes before the engine is stopped. 1300 Series EDi Models WK to WS Preventive maintenance Preventive maintenance periods These preventive maintenance periods apply to average conditions of operation. Check the periods given by the manufacturer of the equipment in which the engine is installed. Use the periods which are shortest.
When the operation of the engine must conform to the local regulations these periods and procedures may need to be adapted to ensure correct operation of the engine. 1300 Series EDi Models WK to WS Schedules The schedules which follow must be applied at the interval (hours or months) which occur first. Every day or every 8 hours Every 5000 hours Every 450 hours or 6 months Every 6700 to 7500 hours Every 900 hours or 12 months Annually Every 3600 hours or 24 months. 7 Renew the canister, part number 26550001, of the coolant filter. Caution: The canister contains a corrosion inhibitor which is circulated around the cooling system as the coolant passes through the canister. It is important that only the genuine correct Perkins canister is used.
W005 W006 User’s Handbook, TPD 1352E, issue 4. 1300 Series EDi Models WK to WS How to fill the cooling system Caution: See 'Coolant specification' on page 31 for details of the correct coolant to be used in the cooling system. If coolant is added to the system during service, it must consist of the same original mixture as used to fill the system.
Caution: The canister contains a corrosion inhibitor which is circulated around the cooling system as the coolant passes through the canister. It is important that only the genuine correct Perkins canister is used. Note: There are two types of coolant filter head: Type 1 1 When the engine has cooled, remove the radiator filler cap to release the system pressure. 1300 Series EDi Models WK to WS How to check the drive belt There is no need to check the tension of the belt as the tension is set automatically.
The condition of the belt should be checked. The belt should be renewed if there are cracks in the belt or if the belt is contaminated by oil or grease. Do not use a strap wrench. 6 Eliminate the air from the fuel filter, see page 24. Caution: It is important that only the genuine Perkins parts are used. The use of wrong parts could damage the fuel injector units. 1300 Series EDi Models WK to WS How to eliminate air from the fuel system If air enters the fuel system, it must be eliminated before the engine can be started.
Air can enter the system if: The fuel tank is drained during normal operation. The low-pressure fuel pipes are disconnected.
1300 Series EDi Models WK to WS How to renew the lubricating oil 1 Operate the engine until it is warm. 2 Stop the engine. 3 Put a container with a capacity of approximately 30 litres (6.5 UK gallons) 32 US quarts beneath the sump.
Remove the sump drain plug (A1) and its washer and drain the lubricating oil from the sump. 1300 Series EDi Models WK to WS How to renew the canister of the lubricating oil filter 1 Put a tray under the filter to retain spilt lubricating oil.
2 Clean thoroughly the outside surfaces of the filter assembly. 3 Use a strap wrench or similar tool to loosen the filter canister. Remove and discard the canister. Ensure that the adaptor (A1) is secure in the filter head. 1300 Series EDi Models WK to WS Air filter Environmental conditions have an important effect on the frequency at which the air filter needs service.
![]()
The filter element must be cleaned or renewed according to the manufacturer's recommendations. Restriction indicator The restriction indicator for these engines must work at a pressure difference of 635 mm (25 in) of water gauge.
1300 Series EDi Models WK to WS How to set the valve tip clearances The valve tip clearance is checked with feeler gauges between the top of the valve stem and the rocker lever (B), with the engine cold. The correct clearance for the inlet valves and the exhaust valves is 0,64 mm (0.025 in).
If you need advice on adjustments to an engine setting or to the lubricating oil change periods which may be necessary because of the standard of the available fuel, consult the Technical Service Department of Perkins International Limited at Peterborough or your nearest Perkins Distributor. 1300 Series EDi Models WK to WS Lubricating oil specification The specification of lubricating oil that is recommended for these engines are API CI-4 or DHD-1. This specification of lubricating oil will provide the necessary protection for your engine. A higher specification of lubricating oil is acceptable. The recommendations indicated below can help to maintain a good cooling system and to protect it against frost and/or corrosion. If the correct procedures are not used, Perkins cannot be held responsible for frost or corrosion damage. 1 If it is possible, use clean soft water in the coolant.
This page is intentionally blank. 1300 Series EDi Models WK to WS Fault diagnosis Problems and possible causes Possible causes Problem Checks by the workshop Checks by the user personnel The starter motor turns the engine too slowly 1, 2, 3, 4 5, 6, 7, 8, 9, 10, 12, 13, 37, 38, 42, 43, 44, 66, 67, 68, The engine does not start 14, 15, 17.
1300 Series EDi Models WK to WS List of possible causes 1 Battery capacity low. 2 Bad electrical connections. 3 Fault in starter motor.
4 Wrong grade of lubricating oil. 5 Starter motor turns engine too slowly.
6 Fuel tank empty. 1300 Series EDi Models WK to WS 47 Lubricating oil pump is worn. 48 Relief valve does not close. 49 Relief valve does not open.
50 Relief valve spring is broken. 51 Fault in suction pipe of lubricating oil pump. 52 Piston is damaged.
Diesel engine exhaust and some of its constituents are known to the State of California to cause cancer, birth defects, and other reproductive harm. Battery posts, terminals and related accessories contain lead and lead compounds.
Wash hands after handling. © 2011 Perkins Engines Company Limited All Rights Reserved.